25/10/2026 14:46:20 25 days ago
Update to FNP 1066 and 1067: The file has been updated following changes to the formulation of EPODUX 209 Base, resulting from regulatory changes concerning certain oxirane compounds. A dedicated ...Read more
Update to FNP 1066 and 1067: The file has been updated following changes to the formulation of EPODUX 209 Base, resulting from regulatory changes concerning certain oxirane compounds. A dedicated testing programme has confirmed that the reformulated version does not result in any deterioration in performance.
13/10/2026 14:51:22 37 days ago
FNP 1139 update: Extension of qualification to PEX 200, 204 and 205 codification (suitable for a CX corrosivity environment in accordance with ISO 12944-2). FNP 1139 is applicable to raw steel and up ...Read more
FNP 1139 update: Extension of qualification to PEX 200, 204 and 205 codification (suitable for a CX corrosivity environment in accordance with ISO 12944-2). FNP 1139 is applicable to raw steel and up to an operating temperature of 400°C.
26/08/2026 16:03:50 85 days ago
Publication of FNP1171: Hybrid liquid/powder coating system for decontaminable interior and exterior anti-corrosion protection and for hydraulic series. This system is a variant of FNP1153 with a ...Read more
Publication of FNP1171: Hybrid liquid/powder coating system for decontaminable interior and exterior anti-corrosion protection and for hydraulic series. This system is a variant of FNP1153 with a water-dilutable primer.
25/08/2026 14:05:39 86 days ago
Update of FNP 1162: Extension of the FNP 1162 qualification to include PIC104 and PIC105, in addition to the PIA, PIB and PID 104 and 105 codifications, up to an operating temperature of 350°C.
Update of FNP 1162: Extension of the FNP 1162 qualification to include PIC104 and PIC105, in addition to the PIA, PIB and PID 104 and 105 codifications, up to an operating temperature of 350°C.
04/08/2026 14:27:09 107 days ago
FNP1188 publication: protection for cold surfaces (T<50°C) made of steel and zinc-coated steel in contact with water, demineralised water and seawater. This paint system complies with codes PLA, ...Read more
FNP1188 publication: protection for cold surfaces (T<50°C) made of steel and zinc-coated steel in contact with water, demineralised water and seawater. This paint system complies with codes PLA, PLB, PLD, PLE 300, 301 and 321
04/08/2026 14:04:16 107 days ago
Update of FNP 1081: extension to codifications HM_600 and HM_621. FNP 1081 can now come into contact with seawater and is suitable for use on steel and metallised substrates.
Update of FNP 1081: extension to codifications HM_600 and HM_621. FNP 1081 can now come into contact with seawater and is suitable for use on steel and metallised substrates.
15/04/2026 08:18:14 218 days ago
The following FNP systems have been depublished: FNP 1137, FNP 1136, FNP 1131, FNP 1075, FNP 1074, FNP 1029, FNP 1028, FNP 710, FNP 278, FNP 1090, FNP 1093, FNP 1089
The following FNP systems have been depublished: FNP 1137, FNP 1136, FNP 1131, FNP 1075, FNP 1074, FNP 1029, FNP 1028, FNP 710, FNP 278, FNP 1090, FNP 1093, FNP 1089
13/04/2026 15:27:13 220 days ago
Update of the FNP 1125 technical data sheet: this powder coating system can now be repaired using two liquid coating systems: FNP 380 and 1170. Please refer to the technical data sheet to select the ...Read more
Update of the FNP 1125 technical data sheet: this powder coating system can now be repaired using two liquid coating systems: FNP 380 and 1170. Please refer to the technical data sheet to select the appropriate repair method based on the codification.
17/03/2026 14:51:44 247 days ago
Publication of FNP1159, a PEX coating system (suitable for a CX corrosivity environment in accordance with ISO 12944-2) for application to raw steel, which can be decontaminated. Based on the ACQPA ...Read more
Publication of FNP1159, a PEX coating system (suitable for a CX corrosivity environment in accordance with ISO 12944-2) for application to raw steel, which can be decontaminated. Based on the ACQPA CX HANV 1554 system
12/03/2026 14:06:50 252 days ago
FNP 1184: Addition of 204 group for extension on service temperature up to 120°C and correction of product trade names.
FNP 1184: Addition of 204 group for extension on service temperature up to 120°C and correction of product trade names.
02/02/2026 08:26:59 290 days ago
Publication of the FNP123 update, which now includes the PIA, GDP and PID series as well as the decontaminable group 231 in addition to the existing PEA, PEB and PEC codifications. Applicable to ...Read more
Publication of the FNP123 update, which now includes the PIA, GDP and PID series as well as the decontaminable group 231 in addition to the existing PEA, PEB and PEC codifications. Applicable to electro-zinc-coated and galvanised steels.
20/01/2026 13:34:37 303 days ago
First publication of FNP 1183 corresponding to PTC/ETC PTL/ETL 010 codification. These are temporary protection systems on coated metal substrates. The maximum service life of these systems is 24 ...Read more
First publication of FNP 1183 corresponding to PTC/ETC PTL/ETL 010 codification. These are temporary protection systems on coated metal substrates. The maximum service life of these systems is 24 months. If you require further information on the conditions of use of this new codification, please contact TEGG.
30/12/2025 10:44:18 324 days ago
First publication of FNP 1155 corresponding to PCB/ECB 300 codification dedicated to application in the water box of heat exchangers/condensers.
First publication of FNP 1155 corresponding to PCB/ECB 300 codification dedicated to application in the water box of heat exchangers/condensers.
19/12/2025 11:12:10 335 days ago
First publication of FNP1180, FNP1181 and FNP1182, corresponding to PTC/ETC PTL/ETL 010 codification. These are temporary protection systems on coated metal substrates. The maximum service life of ...Read more
First publication of FNP1180, FNP1181 and FNP1182, corresponding to PTC/ETC PTL/ETL 010 codification. These are temporary protection systems on coated metal substrates. The maximum service life of these systems is 24 months. If you require further information on the conditions of use of this new codification, please contact TEGG.
19/12/2025 11:07:22 335 days ago
First publication of FNP1162 for PIA/EIA PIB/EIB PID/EID 104 105 codifications up to 350°C
First publication of FNP1162 for PIA/EIA PIB/EIB PID/EID 104 105 codifications up to 350°C